91尻逼视频 I 欧美在线亚洲 I 亚洲人成色77777 I 成人性视频欧美一区二区三区 I 性色av一区 I 99re这里只有精品视频在线观看 I 亚欧毛片 I 韩国精品三级bd I 久操欧美 I 久久久久无码中 I 91久久国产涩涩涩涩涩涩 I 欧美三级香港三级日本三级 I 一区二区三区视频免费看 I 青青草伊人 I 亚洲美女网站 I 女人大p毛片女人大p毛片 I 亚洲一二三区av I 女人做爰视频偷拍 I 蜜臀久久99精品久久久 I 日韩激情三级 I 韩国午夜福利片在线观看 I 亚洲国产精品电影人久久 I 91九色国产蝌蚪 I 黄色www. I 久久久思思 I 婷婷色在线 I 亚洲三级黄色 I 亚洲熟女综合色一区二区三区 I 黄色动漫av I 色香阁综合无码国产在线 I 国产学生不戴套在线看 I 日韩高清av一区二区三区 I 漫画无翼乌羞羞漫画 I 欧洲中文字幕精品 I 欧美xxxx综合视频

Service Hotline

400-9619-700

Index >>

An Attractive Magnetic Concept

02 Mar,2022

6.png

Pat McMullen reveals how passive magnetic bearing systems improve reliability and retrievability of electrical submersible pumps in offshore oil wells

Electrical submersible pumps (ESPs) are widely used as artificial lift tools to remove liquids from oil wells. They are complicated electromechanical systems that must survive harsh downhole conditions that are constantly changing and transient conditions that are difficult to identify. Although there have been improvements to ESP components through the years, their reliability and availability have not yet reached a state that they are cost effective for offshore applications. This is mainly due to the cost of intervention and loss of production in case of any malfunction of the ESP components.

Improvements at the component level have failed to alleviate these failure modes. As a result, operators have accepted the limited reliability and availability of ESPs and have focused instead on implementing new procedures to reduce the time and cost of deployment, rather than undertaking a total redesign of the basic ESP architecture. The average predicted life of ESP systems is about three years. Although alternative intervention techniques can lower the cost of deployment and retrieval of ESPs, the frequency of these interventions and cost of ESPs are still over 30% of the cost of ESP operations for offshore applications. Analysis reveals that eliminating the failure modes related to the electrical system and motor protector, the MTBF of an ESP can be improved to over 10 years.

Disruptive Technology To The Rescue

To address the underlying issues of ESP failure rates, Upwing Energy – working with the support of offshore operators and through the DeepStar Consortium – set out to undertake a “clean sheet” approach and devise a completely new architecture that would simultaneously improve both reliability and retrievability.

To that end, Upwing applied its expertise and experience with permanent magnet technologies to design, develop and test a new robust, scalable magnetic drive system. The Upwing Magnetic Drive System (MDS) hermetically isolates all the failure-prone electrical components from the harsh production fluids by placing them in the annulus of the well as a part of the permanent completion. It also simplifies deployment and intervention using slickline for the system’s mechanical string.

This architecture also eliminates the need for the vulnerable and failure-prone motor protector, which is a very complex, unreliable component in a conventional ESP. The remaining mechanical components, such as the pump, thrust bearing and motor rotor are placed on a retrievable string inside the well tubing. The result is significantly greater reliability and a simplified deployment and recovery system for the mechanical working systems when compared to conventional ESP systems.

Passive Magnetic Bearings

The MDS uses Upwing’s contact-less passive magnet bearing (PMB) technology. The rare earth magnets in the bearing system are positioned to centre the rotor while rotating (regardless of the rotation speed) or in static (non-rotating) condition. While the motor is operating, the bearings do not contribute any losses and are not affected by any fluid that is in the magnetic path of the bearings.

The motor in the retrievable string is driven and supported by the magnetic fields generated in the permanent completion without any mechanical contact between the retrievable string and the permanent completion. Torque and radial centralising force are transmitted through the large gap by way of the magnetic fields.

Since the magnetic fields are produced with permanent magnets, they do not require any control or lubrication for operation. They can operate with large clearances to allow free fluid flow, are easily sealed from the environment and have virtually no bearing rotating losses.

The annulus space in the permanent completion can be filled with corrosion-inhibited completion fluids to further protect all the electrical components. For very hot downhole conditions, higher reliability and power density can be achieved by circulating coolant from the surface to the electrical housing, significantly extending the life of the ESP system. 

A full-scale demonstration of a single passive magnetic bearing has confirmed and further characterised the properties of the deep groove ball bearing system through the support of the DeepStar Consortium.

Next Steps

With continued funding from the Deepstar Consortium, Upwing is advancing the MDS concept to the next level in system development, prototyping and testing all system components and subsystems with the goal of full system demonstration in 2023.


Pat McMullen is chief technology officer at Upwing Energy